DOCUMENTED REPLACEMENT
What to check
03-01583 now points to 111307. Match the equipment model, revision, serial range, voltage, and connector.
- The official manufacturer parts list identifies 111307 in the Electrical-box table for HVE 3000 flood pumper (107977 / F479, 115V).
- Apply this fitment only to HVE 3000 model 107977/F479 units whose nameplate states 115V.
- Confirm the installed assembly, unit serial context, manufacture date when relevant, legacy marking, and current service-list revision before ordering.
- Disconnect both power cords, drain and decontaminate the unit, and follow qualified service procedures before opening the machine.
- The official manufacturer parts list identifies 111307 in the electrical-box assembly for LGR 6000Li dehumidifier (103614 / F600, 115V, R410A, manufactured before March 2022).
- Apply this relationship only to Dri-Eaz LGR 6000Li model 103614/F600 equipment with a 115V nameplate, an R410A refrigerant label, and a manufacture date before March 2022.
- Do not extend this relationship to equipment governed by parts list 125298E, to any R32 machine, or to equipment whose date code and refrigerant label cannot be confirmed.
- Suffixless and S-suffixed service numbers are separate manufacturer identifiers. Do not infer equivalence, supersession, or interchangeability without explicit evidence.
- Confirm the complete nameplate, refrigerant label, serial and date code, installed marking, physical location, connector or dimensions, required quantity, and current manufacturer instructions before ordering.
- Disconnect power before service. Mains-power, control-board, motor, pump, and sealed-refrigeration work requires qualified service and current manufacturer procedures.