DOCUMENTED REPLACEMENT

13-00053WAS REPLACED BY120300
Part confirmed

What to check

13-00053 now points to 120300. Match the equipment model, revision, serial range, voltage, and connector.

  • The official manufacturer parts list identifies 120300 at find 85 for DrizAir 1200 dehumidifier (104677 / F203-A, 115V, R410A).
  • Apply this fitment only to DrizAir 1200 model 104677/F203-A units whose nameplate and refrigerant label state 115V and R410A.
  • Do not use this relationship for the separately documented R32 version.
  • Confirm the find-number location and current service-list revision before ordering.
  • The manufacturer says the dust cap is included with the wheel; do not add a second dust cap unless the installed assembly is missing it.
  • The official manufacturer parts list identifies 120300 in the Lower-rear table for HVE 3000 flood pumper (107977 / F479, 115V).
  • Apply this fitment only to HVE 3000 model 107977/F479 units whose nameplate states 115V.
  • Confirm the installed assembly, unit serial context, manufacture date when relevant, legacy marking, and current service-list revision before ordering.
  • Disconnect both power cords, drain and decontaminate the unit, and follow qualified service procedures before opening the machine.
  • Confirm whether the installed wheel includes or separately requires dust cap 103879 before ordering.
  • The official manufacturer parts list identifies 120300 in the outer housing for LGR 6000Li dehumidifier (103614 / F600, 115V).
  • Apply this relationship only to Dri-Eaz LGR 6000Li 103614/F600 equipment with a 115V nameplate.
  • Confirm the installed marking, physical location, required quantity, and current manufacturer instructions before ordering.
  • Do not use this mechanical relationship to infer the equipment refrigerant generation.